Standard method: one-family dwelling load

Work a one-family dwelling load calculation the standard way: 3 VA/ft², 1,500 VA circuits, Table 220.45 tiers, range, dryer, appliances, then amps.

STEP 1 · START WITH THE FLOOR AREA

Measure the house from its outside dimensions and multiply by 3 VA per square foot (220.41). Leave out the garage, open porches, and unfinished space that can't become living space (220.5(C)). A 2,000 ft² house starts at 6,000 VA. In a dwelling, that figure already covers the general-use receptacles, so you don't count them again.