From circuit to code, one idea at a time.
Every lesson opens with a real job situation, lets you move the idea with your own hands, and ends with exam-style practice. 5 lessons are free for everyone; a free account opens 12. Tap a unit to see its lessons.
UNIT 1 Electrical theory · 3 lessons · 34 min
Ohm's law and the power formulas
Learn E = I × R and P = E × I by moving sliders, then solve any volts, amps, ohms or watts question on the journeyman exam in two steps.
Series and parallel circuits
See why current is shared in series and voltage is shared in parallel. Solve total resistance, current and voltage drop questions fast.
Power, energy (kWh) and efficiency
Watts vs kilowatt-hours, what a load costs to run, and how efficiency links input and output power for motors and transformers.
UNIT 2 AC, power factor & three-phase · 3 lessons · 36 min
AC basics: frequency, peak, RMS and reactance
What 60 Hz means, why 120 V is an RMS value with a 170 V peak, and how coils and capacitors push back on alternating current.
Power factor and the power triangle
kW, kVAR and kVA as a right triangle. Find power factor, real power and line current, and see why capacitors cut current on motor loads.
Three-phase: wye, delta and the √3 factor
Why 120 V phases make 208 V, how 480Y/277 V works, line vs phase current in delta, three-phase amps from kVA, and the 208 V high leg.
UNIT 3 Navigating the NEC · 3 lessons · 35 min
How the NEC is organized (and how to find anything fast)
Chapters, articles, parts, sections, exceptions and tables: learn the NEC's layout so you can find any answer fast in an open-book electrician exam.
Article 100 definitions that decide exam questions
Readily accessible, within sight, continuous load, grounded vs. grounding conductor, bonding jumpers, dwelling unit: the NEC definitions exams test most.
Article 110: terminations and working space
Article 110 for the electrician exam: listing and labeling, termination temperature, Table 110.26(A)(1) working space depth, width, height, entrances.
UNIT 4 Branch circuits & receptacles · 3 lessons · 37 min
Branch-circuit ratings and the 125 % rule
Branch-circuit ratings, continuous loads at 125 %, receptacle ratings and the 80 % and 50 % load limits of NEC 210.19 through 210.24, made simple.
Where GFCI and AFCI protection is required
NEC 210.8 GFCI and 210.12 AFCI rules for dwellings and commercial buildings: which locations, which circuits, and the traps exams use.
Required dwelling receptacle outlets and circuits
Dwelling receptacle layout per NEC 210.52: the 6-ft and 24-in. rules, required 20 A circuits in 210.11(C), service receptacles and lighting outlets.
UNIT 5 Conductors & ampacity · 3 lessons · 35 min
Reading Table 310.16 and termination limits
Read NEC Table 310.16 the right way: insulation columns, 75 °C lug limits from 110.14(C), and the 240.4(D) small-conductor caps exams test.
Ambient correction and bundling adjustment
Correct Table 310.16 ampacity for hot locations and adjust for more than three current-carrying conductors, starting from the 90 °C column.
Voltage drop: the 2KIL/CM method
Calculate voltage drop with VD = 2KIL/CM, apply the 3 % and 5 % recommendations, and upsize conductors for long single- and three-phase runs.
UNIT 6 Overcurrent protection · 2 lessons · 23 min
Overcurrent protection basics
Standard breaker and fuse sizes, the next-size-up rule of 240.4(B), and the 125 % rule for continuous loads on conductors and overcurrent devices.
Feeder taps and where OCPDs may go
The 10-ft and 25-ft feeder tap rules of 240.21(B), and where 240.24 allows overcurrent devices: readily accessible, 6 ft 7 in. max, not in bathrooms.
UNIT 7 Grounding & bonding · 3 lessons · 37 min
Grounding vs bonding: the path that trips the breaker
Why a ground rod can't trip a breaker, what the main bonding jumper does, and why the neutral and ground stay apart past the service. NEC 250.4, 250.24.
The grounding electrode system and GEC sizing
Which electrodes count, the 8 ft rod, 6 ft spacing and 25 Ω rules, and how to size the grounding electrode conductor from Table 250.66.
Equipment grounding conductors and bonding
What counts as an EGC, sizing from Table 250.122 and upsizing, detached buildings, water and gas pipe bonding, and the intersystem bonding termination.
UNIT 8 Wiring methods, boxes & raceways · 3 lessons · 36 min
Box fill: count every cubic inch (314.16)
Learn NEC 314.16 box fill the fast way: count conductors, clamps, studs, devices and grounds, then pick a box from Table 314.16(A).
Conduit fill with Chapter 9 tables
Size conduit like the exam expects: Chapter 9 Table 1 fill limits, Table 4 and Table 5 areas, the Annex C shortcut, and the 60 % nipple rule.
Protect, bury and support wiring methods
NEC rules journeymen get tested on: nail plates (300.4), burial cover (300.5), NM and EMT support, 360° bend limit, free conductor length and pull boxes.
UNIT 9 Load calculations & services · 3 lessons · 34 min
Standard method: one-family dwelling load
Work a one-family dwelling load calculation the standard way: 3 VA/ft², 1,500 VA circuits, Table 220.45 tiers, range, dryer, appliances, then amps.
Optional method for a one-family dwelling
The 220.82 optional dwelling calculation: lump the general loads, take 10 kVA at 100 % and the rest at 40 %, then add the largest heat or AC load.
Services: conductors, clearances, disconnects
Size dwelling service conductors with the 310.12 83 % rule, set overhead clearances (230.9, 230.24, 230.26), and place and rate the service disconnect.
UNIT 10 Motors & air conditioning · 3 lessons · 34 min
Motor full-load current: tables, not nameplates
Size motor conductors from Table 430.248 and 430.250 full-load current, at 125 % for one motor and with the 430.24 rule for several.
Motor overloads and short-circuit protection
Set motor overloads from nameplate current (125 % or 115 %) and size the short-circuit device from Table 430.52(C)(1), with the next-size-up rule.
Motor disconnects and Article 440 AC equipment
Motor disconnects in sight and at 115 %, plus Article 440 basics: MCA, MOCP and the AC disconnect within sight of the unit.
UNIT 11 Transformers & generators · 3 lessons · 35 min
Transformer calculations: kVA, ratio and current
Find transformer primary and secondary current from kVA, single- and three-phase, and use the turns ratio to move between sides.
Transformer overcurrent protection
Size transformer primary and secondary overcurrent devices with Table 450.3(B), when to round up, and the basics of secondary conductors.
Generators and transfer equipment
Generator conductors at 115 %, why transfer equipment is required, and where the neutral bond goes for portable and standby generators.
UNIT 12 Special occupancies & equipment · 4 lessons · 47 min
Hazardous locations: classes, divisions and seals
Class I, II and III, Division 1 vs 2, the Zone system, conduit seals in 501.15, and how garages and gas stations are classified.
Pools and spas: GFCI, distances and bonding
Article 680 made simple: pool receptacle distances, GFCI for pumps and receptacles, equipotential bonding, and underwater luminaire basics.
Solar PV and EV charging: the 125 % rules
PV current calcs (Isc × 125 %, then 125 % for conductors), rapid shutdown basics, and EV charger circuits sized as continuous loads with GFCI.
Emergency, standby, temporary wiring and signs
Articles 700, 701 and 702 compared (10 s, 60 s, no limit), keeping emergency wiring separate, GFCI for temporary power, and sign outlet basics.